FUCARE provides comprehensive blast protection products for shelters including blast valve, blast damper, blast door, blast window and other supporting lines.
Your current location:Home>>PRODUCTS>>Blast damper

FC-BRV-02-E Rapid Blast Damper

FC-BRV-02-E rapid blast dampers are specifically developed for those applications where high air flow rate and blast protection are required. It could stand the overpressure up to 200KPa reflected with long duration and shut off in milliseconds. It could also stand multiple blast impacts and maintain full functions after blasts.

Compared with FC-BRV-02-S standard version, FC-BRV-02-E enhanced version carries a debris shield which adds extra safety margin regarding the high speed hits by flying debris.

Features&BenefitsSpecificationsPNCertificatesApplicationLiterature
+ Features&Benefits
  •   Stand strong blast impulse

Able to stand multiple blast impacts and maintain all functions after blasts.

  •   High blast impulse block rate

Approximate 100% blast impulse block rate to assure the sufficient protection.

  •   Unparralled rapid response

Completely closed within 8ms under 200KPa peak pressure reflected and this assures minimum passing through impulse.

  •   High ventilation volume

High air flow based on normal open position. A 500*500 blast damper could provide exhaust air flow rate up to 3800 m3/h at pressure differential 100Pa.

  •   Automatic-reset

Able to retrieve ventilation function automatically after blast.

  •   High corrosion resistant performance

Made of chemical-resistant material and fit all corrosive conditions.

  •   ATEX certified

Safely work in explosive atmospheres.


+ Specifications

 Designed peak pressure

 200KPa Reflected

 Designed blast duration

 20ms

 Closing time

 <8ms (200KPa reflected)

 Blast impulse block rate

 >98.5% (200KPa reflected)

 Operating temperature

 -30ºC to 285ºC

 ATEX Certification

 Certification No. TÜV 15 ATEX 7741 X    

 Ⅱ2 G c ⅡC T6...T2

 Ⅱ2 D c ⅢC T70℃...T285℃

+ PN

ATO PN:   FCBRV02E[A][B][C][D]

Code

Options

Descriptions

A

Material of damper

 1-Stainless Steel 316L

 2-Stainless Steel 304L

 3-Hot galvanized steel

 4-Epoxy coated steel
    (Non-ATEX)

B

Mounting Type

IW–In the wall

OW–On wall surface

D–Duct connected

C

Width

(mm)

0300

0500

0700

1000

1200

1500

D

Height

(mm)

0300

0500

0700

1000

1200

1500

+ Certificates
Product is type tested at AMCA(US), TUV(Germany). Test reports are available upon request.
+ Applications
  • OGP
  • Chemical
  • Power
  • Marine
  • Mining
  • Civil defense

+ Literature